OCV test equipment for prismatic battery
HYNN OCV tester can automatically test for the open circuit voltage, AC internal resistance and shell cover insulation (the voltage between the positive electrode and shell) of the single cell in the battery tray. OCV testing is the essential process of battery manufacturing. Combining battery testing with battery tray for batch testing or single testing, it can reach to fast and reliable testing results. The production management and control system automatically calculates the K value according to the test data, and automatically completes the binding of the production data information, automatic saving and binding information. Data can be export through internet connection.
详情信息

Test items

1. Test of the battery open circuit voltage (OCV).

2. Test of the battery AC internal resistance (ACR).

3. Case voltage test.

 

System characteristics

1. The equipment can be made on demand flexibly matched outside the output line or bridged inside the output line.

2. Embedded design is applied to the man-machine interface. The display height and operation platform are designed in accordance with the requirement of ergonomics.

3. High precision testing instrument is employed, which ensures a high precision as well as a stable and reliable performance.

4. OCV test device, with the independent research and development of intellectual property rights, can be seamlessly connected with automatic logistics equipment and process equipment in the last and nest procedures, which guarantees a high precision as well as a stable and reliable performance.

 

Functional characteristics

1. The internal resistance and open circuit voltage are tested independently with respective instruments. 34461A 6.5-bit meter is employed for voltage test, which ensures a high precision as well as a stable performance, while HIOKI 3562 meter is used for the internal resistance test, with the test resolution as high as 0.0001mΩ.

2. The probe cables of the battery test, intertwined with magnetic separation paper, are connected to the test instrument after being sheathed with stainless steel sealing trough, to avoid magnetic interference in the OCV test result.

3. The OCV auto-zero calibration function: The automatic zero fixture allows the cycle self-defining to achieve automatic zero calibration of the instrument of the open circuit voltage and AC internal resistance acquisition, which can substantially lower the impact of system test on the production and guarantee the trace of testing precision. The data will be automatically uploaded and kept in the management control system after the test.

4. It has the functions of testing the charged battery shell, picking out and removing bad OCV non-performing quantity. 

 

Equipment parameters


S/N

Content

Specification

1

Equipment power

2KW

2

Voltage test range

0~6V

3

Internal resisitance test range

0.01mΩ~3.1000Ω

4

Voltage test accuracy

±0.01%rdg.±3dgt (V)

5

Internal resisitance test accuracy

±0.5%rdg. ±10dgt

6

Number of channels

32 Channels/set




热门推荐更多
5V power supply cabinet 5V power supply cabinet

HYNN power battery testing system is mainly designed for power battery. Designed with high accuracy, high flexibility and high performance, it can meet all test requirements for battery with the range of 0-5V (Voltage), 20mA-30A-400A (Current).

Model:DECT0530A, DECT0560A, DECT05100A, DECT05200A, DECT05400A

Negative pressure formation needle bed Negative pressure formation needle bed

HYNN negative pressure formation needle bed applies with six-sided protection scheme. Each storage position layer is isolated with stainless steel plate and fire proof rock wool; Needle bed is equipped with water fire protection and gas fire protection; Storage position is designed with smoke and temperature sensors. Safe and reliable, it is the most popular and advanced design scheme for ternary cells and lithium ferrum battery testing nowadays.

Capacity-grading needle device for prismatic battery Capacity-grading needle device for prismatic battery

HYNN negative pressure formation needle bed applies with six-sided protection scheme. Each storage position layer is isolated with stainless steel plate and fire proof rock wool; Needle bed is equipped with water fire protection and gas fire protection; Storage position is designed with smoke and temperature sensors. Safe and reliable, it is the most popular and advanced design scheme for ternary cells and lithium ferrum battery testing nowadays.

DCIR tester for prismatic battery DCIR tester for prismatic battery

Through the integration of PC computer, PLC and hardware, HYNN DCIR tester can accurately measure the DC internal resistance and open circuit voltage, realizing the perfect combination with the automation. The DCIR tester can not only test for the important parameters of battery measurement, but also fulfill the development of industrial automation and technology.

Prismatic battery classification machine Prismatic battery classification machine

HYNN battery level grading machine automatically scans barcode for the incoming battery, selecting and grading finished batteries according to some set rules. The user can set rules and numbers of levels for grading. Programming is proceed via data of battery manufacturing process. The formation management control system can automatically grade and upload grading results data according to data from former process. The grading machine can perfectly connect with the automatic logistics equipment and process equipment.